Controlador de Temperatura e Processo - Série 8500 Microprocessado e totalmente programável, Self-Tune PID, formato horizontal ou vertical 1/8 DIN. | The Dwyer Series 8500 Temperature/Process Control provides an impressive selection in a compact, economical 1/8 DIN package. Choose from two case styles in horizontal or vertical formats. Features include on-off, time proportioning, proportional, PI, PD or full PID control - fully programmable from the front panel - or use Self-Tune® PID. Inputs are selectable from a variety of thermocouple types including J, , T, E, N or L; DIN NIST or Ni RTDs. Output choices include solid state relay, mechanical relay, 5 VDC - ideal for driving an external SSR - or isolated 4-20 mA proportional current. An optional programmable alarm provides a full array of alarm action configurations including high alarm, low alarm and high/low guardband alarm. Manual reset, power-up inhibit and power interrupt reset provide additional alarm flexibility. A water and corrosion resistant front panel (NEMA 4X, IP65), input fault timer, digital input filter, Self-Tune® ramp to setpoint, four password protected security levels and °F or °C display selection are all standard. Entire electronics package is easily field replaceable without wiring changes thanks to the removable front panel.
Model No.1
| Alarm
| Input
| Output 2
| D85011-(1)(0) D85012-(1)(0) D85013-(1)(0) D85015-(1)(0) D85021-(1)(0) D85022-(1)(0) D85023-(1)(0) D85025-(1)(0) D85111-(1)(0) D85112-(1)(0) D85113-(1)(0) D85115-(1)(0) D85121-(1)(0) D85122-(1)(0) D85123-(1)(0) D85125-(1)(0)
| No No No No No No No No Yes Yes Yes Yes Yes Yes Yes Yes
| Thermocouple Thermocouple Thermocouple Thermocouple RTD RTD RTD RTD Thermocouple Thermocouple Thermocouple Thermocouple RTD RTD RTD RTD
| SSR 5 VDC Relay 4-20 mA SSR 5 VDC Relay 4-20 mA SSR 5 VDC Relay 4-20 mA SSR 5 VDC Relay 4-20 mA
| 1 Specify suffix 1 for horizontal or 0 for vertical mounting. 2 When ordering a control to operate contractor or solenoid loads greater than 100 mA, select the SSR output instead of the Relay. If the relay is selected, order part number A-600. R/C snubber. | PHYSICAL DATA
Input Impedance: | | Thermocouple + 3 megohms minimum, RTD current = 200 A maximum | Sensor Break or Short Protection: | | De-energizes control output to protect system | Setpoint Range: | | Selectable | Display: | | Two 4 digit, 7 segment LED; 0.4" (10 mm) high - horizontal models; 0.3" (7.62 mm) high -vertical models | Control Action: | | Selectable for Reverse (usually heating) or Direct (usually cooling) | Accuracy: | | ±0.25% of span, ±1 degree | Resolution: | | 1 degree or 0.1 degree | Temperature Stability: | | 2.3 V/°F (4 V/°C) typ., 4.5 V/°F (8 V/°C) maximum | Common Mode Rejection: | | 140 db minimum at 60 Hz | Normal Mode Rejection: | | 65 db typical, 60 db at 60 Hz | Isolation: | | Relay and SSR outputs; 1500 VAC. 0-20 mA output; 500 VAC. 5 VDC output is not isolated | Power Consumption: | | 5 VA maximum | Supply Voltage: | | 100 to 240 VAC nominal, +10%-15%, 50 to 400 Hz, single phase; 132 to 240 VDC +10%-20% | Operating Temperature Range: | | 14 to 131°F (-10 to 55°C) | Storage Temperature Range: | | -40 to 176°F (-40 to 80°C) | Humidity Range: | | 0 to 90% up to 104°F (40°C) non-condensing, 10 to 50% at 131°F (55°C) | Memory Backup: | | Non-volatile memory. No batteries required | Control Output Ratings: | | SSR: 2.5 A at 240 VAC resisting at 77°F (25°C). De-rate to 1.25 A at 130°F (55°C) Relay: SPDT, 10 A at 240 VAC resistive Alarm Relay: SPST, 3 A at 240 VAC resistive Switched Voltage (non-isolated): 5 VDC at 20 mA Proportional Current: 0-20 mA DC, scaleable into 600 ohms maximum.
| Weight: | | 10 oz. (369 g) | SUGGESTED SPECIFICATIONS Temperature/Process Controller shall be 1/8 DIN (horizontal)(vertical), microprocessor based with two four digit LED displays for setpoint, alarm status and °F or °C. Input shall be (selectable J, K, T, E, N or L thermocouple)(DIN-RTD). Output shall be (SSR)(5 VDC)(Relay)(Isolated 4-20 mA) programmable for manual or automatics Self-Tune® PID control (with)(without) alarm. Front panel shall be designed to meet NEMA-4X, IP 65 ratings for weather and corrosion resistance. Accuracy shall be ±0.25% of span, ±1 degree. Temperature/Process controller shall be Dwyer Model D85 _____.
| |