Precision RTD (Resistance Temperature Detector) offers excellent accuracy and stability over a wide temperature range. Industry standard 3 wire 100 OHM (DIN) probes area available in various mounting configurations including quick disconnect plugs, liquid sealing bushings, ceramic connectors or direct duct mounting with 4-20 mA transmitter. Ideal for air or liquid immersion.

PHYSICAL DATA
Sensor Type:   Wire wound
Temperature Range:   -100°C to 200°C (-148 to 392°F)
-100°C to 550°C (-148 to 1022°F)
Maximum Temperature:   550°C (1022°F)
Maximum Pressure:   250 PSIG
Probe Diameter:   A=1/4" B=1/8"
Probe Length:   6, 9, 12, 18, or 24"
Probe Material:   Stainless Steel
Standard:   DIN 43760
Model Number
Length
"L" Dim.

Operating
Range

1/4" Dia.
1/8" Dia.
RTD-A06-C2L
RTD-A06-C6L
RTD-A12-C2L
RTD-A12-C6L
RTD-A18-C2L
RTD-A18-C6L
RTD-B06-C2L
RTD-B06-C6L
RTD-B12-C2L
RTD-B12-C6L
RTD-B18-C2L
RTD-B18-C6L
6"
6"
12"
12"
18"
18"
-100 to +200°C
-100 to +550°C
-100 to +200°C
-100 to +550°C
-100 to +200°C
-100 to +550°C

APPLICATIONS
Typical applications are: airducts, bearing temperature, oil temperature indicator, soldering equipment, ovens, environmental test chambers, pharmaceutical mfg., food processing, plastic molding, petroleum & chemical processing, electric generating plants, etc.

SUGGESTED SPECIFICATIONS

Suggested Specification: Resistance temperature detector probe shall be wire wound platinum with (1/4")(1/8") diameter 316SS sheath, 36 in. leads and spade lug connectors. Unit for (200°C)(550°C) operation shall meet DIN standard 43760. Temperature Detector shall be Dwyer Model No. RTD-_____-_____.

 


VOLTAR  |  ADICIONAR AO OR´┐ŻAMENTO